Back

Used Equipment Store

Account Benefits

Get a customised view of the Used Equipment Store

Manage your details to get quick responses by the team

Stay up-to-date on specials, price and availability

Already have an account? Log In

Create Your Account

Your browser limits use of the Used Keysight Equipment website.
Please consider switching to a current version of Chrome, Firefox, Edge or IE11 to use this site.

도움이 필요하신가요 ?

Contact us with any question regarding your used Keysight equipment purchase!

Back

Product selection and configuration assistance

General technical question

Availabilty, warranty extensions, calibration plans, additional software options, education discounts etc.

Question about this offer

Please call an expert at:

1 800 829-4444
Press #, then 2

Hours:
7am – 5pm MT, Mon– Fri

or find your Local Keysight Contacts

도움

Check Shipping

Find out if this unit can be shipped to your country

ID: P08-100184

Keysight N5292A-200

Millimeter-wave Test Set Controller for PNA/PNA-X Network Analyzer Series / 2-port

ID: P08-100184
Keysight N5292A-200 2-port
Actual instrument
-N5292A-200-0

Keysight N5292A-200

Millimeter-wave Test Set Controller for PNA/PNA-X Network Analyzer Series / 2-port

거의 새 제품과 같이 복원
교정 완료
거의 새 제품과 같은 보증 기간
액세서리 포함
설정(구성) 가능한
키사이트 케어 이용가능

정가 USD 50,088.00 25% 할인
USD 37,566.00 세금 미포함
다른 할인과 중복 사용 불가.

전문가 및 산업용으로만 사용 가능
말레이시아 출발 배송
United States 으로의 배송은 8 주 이내 소요됩니다.

Cannot ship to:

European Union
Switzerland
Norway
Turkey

Unit only ships within China.

Unit ships worldwide.

Keysight N5292A-200 2-port

키사이트 프리미엄 중고

Keysight  N5292A-200

From

USD 37,566.00 25% 할인

설치 옵션

200Test set, 2-port

추가 가능한 옵션

N0CNo Interconnect cables required
222Interconnect kit for 2-port test set and 2-port VNA with 3.5 mm ports
224Interconnect kit for 2-port test set and 2-port VNA with 2.4 mm or 1.85 mm ports
242Interconnect kit for 2-port test set and 4-port VNA with 3.5 mm ports
244Interconnect kit for 2-port test set and 4-port VNA with 2.4 mm or 1.85 mm ports
422Interconnect kit for 4-port test set and 2-port VNA with 3.5 mm ports
424Interconnect kit for 4-port test set and 2-port VNA with 2.4 mm or 1.85 mm ports
442Interconnect kit for 4-port test set and 4-port VNA with 3.5 mm ports
444Interconnect kit for 4-port test set and 4-port VNA with 2.4 mm or 1.85 mm ports

Adding options and accessories may impact shipping times

Request a customized version of this model by requesting a Custom Quote

제품 사양


  • Accurate and stable measurements with dedicated Interface connectors and cables to the frequency extenders
  • Available adapter kits for existing OML/VDI frequency extender modules (required power supplies for extenders)

The N5292A millimeter-wave controller provides 2- or 4- port interface capability to the millimeter-wave frequency extender modules and with a PNA or PNA-X Series B model network analyzers.

  • When used in conjunction with the millimeter-wave test head modules and the PNA/PNA-X Series B models, it provides all the features and functions of a full 2/4-port S-parameter test.
  • Single cable interface to the N5293/95A modules supplies RF, LO and IF signals to/from the millimeter-wave test head modules.
  • The N5292A returns the down-converted reference and test IF signals to the PNA/PNA-X for process and display.
  • A breakout cable assembly allows the N5292A to interface to OML/VDI frequency extender modules.
  • The N5292A has an optical detection scheme which automatically detects when a N5293/95A module is connected.
  • The N5292A allows for direct access to the Test and Reference IF signals from the modules.

Note: The N5292A millimeter-wave controller supports PNA/PNA-X Series B model network analyzers 26.5 GHz and above.

When external connected to VDI/OML modules an external power supply is required.

액세서리


Standard accessories included.

For additional accessories, please search Keysight Accessories

시작할 준비가 되셨나요 ?

무엇을 얻게 될까요

  • Keysight N5292A-200 Network Analyzers
  • 최신의 교정
  • 거의 새 제품과 같은 스탠다드 액세서리
  • 거의 새 제품과 같은 보증 기간
  • 합의된 설정(구성)

What You Can Add

  • 보증 기간 연장
  • 키사이트 케어 보장 / 연장
  • 교정 계획
  • 소프트웨어 (모델에 따라 상이)

여전히 구매에 대한 확신이 없으신가요 ?

궁금한 사항이 있으시면 언제든지 연락주세요. 도와드릴 준비가 되어 있습니다.!

문의하기

자주 묻는 질문

키사이트 새 제품, 키사이트 프리미엄 중고 및 키사이트 중고 장비 간의 주요 차이점은 무엇인가요?

  키사이트 새 제품 키사이트 프리미엄 중고 키사이트 중고
할인 해당없음 최대 70% 최대 90%
상태 새 제품 거의 새 제품 작동 상태 ¹
펌웨어 최신 업데이트됨 있는 그대로
교정 전체 전체 목록에 따라
액세서리 새 제품 새 제품 목록에 따라
보증기간 1~5년 ² 거의 새 제품 90일 보증기간
맞춤 설정 가능 가능 제한있음

키사이트 프리미엄 중고에 대해 여기에서 자세히 알아보기

개인적인 요구에 맞춘 장비 설정(구성)이 가능할까요?

키사이트 프리미엄 중고 장비의 경우 일반적으로 사용자 맞춤 설정이 가능합니다. 대부분의 키사이트 프리미엄 중고 장비는 사용자가 필요로 하는 대로 제품을 설정(구성)할 수 있습니다. 업그레이드 옵션 및 응용 소프트웨어 역시 할인이 적용이 가능합니다.
키사이트 프리미엄 중고 장비를 사용자 맞춤 설정을 할 경우 해당 품목의 배송 및 납기가 변경될 수 있습니다.

일부 키사이트 중고 제품의 경우 사용자 맞춤 설정이 불가한 경우가 있습니다(제한 사항 포함). 제품 페이지의 연락 옵션을 사용하여 저희 이스토어 팀과 확인하실 수 있습니다.

어떤 액세서리가 포함되어 있나요?

키사이트 프리미엄 중고 장비는 일반적으로 새 제품과 동일한 액세서리와 보증 기간이 제공됩니다.

다른 액세서리를 포함할 수 있나요?

현재 우리는 목록에 포함된 액세서리만 제공합니다. 다른 액세서리는 별도의 비용이 발생할 수 있으며 키사이트 중고 또는 키사이트 프리미엄 중고 장비를 구매할 때 별도로 구매할 수 있습니다.

추가 액세서리 또는 지원을 원하는 경우 코멘트란에 언급해주세요.

별도 또는 추가 주문을 하려면 지역 키사이트 사무실 또는 여기에서 키사이트 협력업체로 연락주세요. 또는 귀하의 지역 여기에서 사용 가능한 경우 온라인 스토어를 확인하세요.

계정 만들기와 모델, 가격 및 가용성 추적

지금 가입하세요.

교육 및 비영리 목적 고객은 추가할인 가능

자세히 알아보기

Network + Impedance Analyzers Quick-Facts

What is a Vector Network Analyzer?

High-performance Vector Network Analyzers (VNA) are used to characterize and analyze RF and Microwave devices such as amplifiers, filters, power dividers/combiners, switches, antennas, and more. VNAs provide engineers with accurate device measurements including S-parameters, noise figures, return loss, and more.

What is a Vector Network Analyzer used for?

A Vector Network Analyzer, a stimulus response testing equipment, is commonly used for research and development, design validation, failure analysis, and production testing by measuring the frequency response of component(s).

Does a VNA need to be calibrated?

Yes, all VNAs are calibrated to ensure the highest quality results. The calibration process involves adjusting the instrument to eradicate the hardware systematic errors using traceable standards for accuracy and phase measurements.

How do you calibrate a Vector Network Analyzer?

The calibration process can be done manually or automatically, but in most cases, the manual method is used. The common methods of calibration include SOLT and TRL based on different parameters to remove systematic errors. Manual calibration involves selecting a known stimulus signal from a list of available signals within the VNA's software, then adjusting the amplitude and phase until the value corresponds to that from the known stimulus source. The network analyzer should be periodically calibrated with a reference calibrator to ensure the analyzer is measuring correctly. Periodic calibration guarantees the match with International standards.

Does a VNA have error correction?

Some VNAs have built-in error correction that may compensate for a variety of errors including thermal drift, time delay, source-load mismatch and optical path length variations.

What is the difference between a Vector Network Analyzer vs Network Analyzer?

A Vector Network Analyzer measures the amplitude as well as phase characteristics of one and two-port devices such as wireless components, microstrip lines, and branched structures.

A Network Analyzer measures the network parameters of two-port and arbitrary number of ports devices such as amplifiers, filters etc.

What is the difference between a Vector Network Analyzer vs Spectrum Analyzer?

A Vector Network Analyzer measures complex component specifications at specific frequencies using a signal generator and a receiver.

A Spectrum Analyzer measures power across an entire frequency spectrum of the applied signal using a receiver only.

What is the difference between a Vector Network Analyzer vs Oscilloscope?

An oscilloscope measures external signals by representing voltage waveforms as a function of time, while a Vector Network Analyzer measures both the amplitude and phase monitoring the response of a network.

How does a VNA measure S11?

A VNA measures S11 by introducing a stimulus signal into the port of the device being tested, then measuring the reflected signal. The frequency at which this reflection occurs is then used to calculate S11.

What is the S21 parameter?

S21 is used to measure how well a device rejects signals that are passed through the input port and reflected on the output port. The power transferred from the first port to the next can be determined using the S21 parameter.

What are propagation and channel modeling?

Propagation and channel modeling is a technique for estimating the performance of wireless communications antennas and their effect on cell coverage.
The most significant parameters in propagation and channel modeling are path loss, Fresnel zone, path attenuation, and multipath fading.

What is a Smith chart?

A Smith chart is a graphic representation of a particular type of circuit operation. It shows the impedance, admittance, and conductance of an amplifier or other system component as it relates to frequency or voltage. In order to understand how a Smith chart operates, it is important to know the basics of transmission line theory.

What is Voltage Standing Wave Ratio?

Voltage standing wave ratio is the measure of the non-reactive voltage received at a point in space relative to cause by an AC source, thus representing the reflected power from the antenna source. It is typically specified as volts per meter (V/m) or millivolts per meter (mV/m).

How does a Vector Network Analyzer measure phase?

A Vector Network Analyzer measures phase by introducing a stimulus signal into the port of the device being measured. The degree of phase shift is then noted. A separate calibration is used to determine the degree of phase shift when no stimulus signal is applied.

How does a VNA measure amplitude?

A VNA measures amplitude by introducing a stimulus signal into the port of the device, then measuring the strength. The magnitude of the reflected signal is then used to calculate amplitude.

What are amplitude properties?

Amplitude properties include the amplitude at a particular frequency, amplitude ranges, amplitude linearity, and amplitude ratio measurements.